Square D HU36 Heavy Duty Three Phase Non-fused Disconnects 60 A NEMA 1 600 V
HU36 Series Heavy Duty Three Phase Non-fused Disconnects
- According to the National Electric Code, section 690.15, PV arrays must have a disconnecting means to isolate the inverter from the PV power source.
- Utility grid-tie inverters that utilize PV arrays with voltages above 250VDC require a disconnect rated for 600VDC to perform this function
- Square D disconnects For Use With grid-tie inverters that don't already have pre-built disconnects
- It is nonfusible, rated at 600 volts DC
- The DC input of up to two sub-array can be connected to the safety switch and it is outdoor rated so it can be located close to the panels
- Can be used for disconnecting up to three PV arrays for three grid-tie inverters
- It has wiring lugs that are rated to accept two #14 to #10 wires in each lug
Brand | Square D |
NEMA Rating | NEMA 1 |
Number of Phases | 3 Phase |
Wire Size | (1) 14 - 2 AWG |
Voltage | 600 V |
Number of Poles | 3 Pole |
Enclosure Type | N1 Enclosure |
Disconnect Type | Non-fused |
Amperage | 60 A |
Material | Steel |
Locking Square D™ Heavy Duty Safety Switch Handles to ON Position | Schneider Electric Support
Tutorial discussing the options for locking the handle of a Square D™ Heavy Duty Safety Switch into...
Installing Replacement Cover Latch & Spring on 30-200A Safety Switches | Schneider Electric Support
Tutorial for installing the replacement cover latch and spring kit on Square D General, ...
Differentiating Square D™ General Duty & Heavy Duty Safety Switches | Schneider Electric Support
Overview comparing the similarities and differences in physical characteristics and features of...
Demonstrating the Dual Cover Interlock on Heavy Duty Safety Switches | Schneider Electric Support
A demonstration of the Dual Cover interlock feature of Square D Heavy Duty Safety Switches which...
Installing RFK10 Class R Fuse Kits into 100A Series F Safety Switches | Schneider Electric Support
Tutorial for installing RFK10 Class R Fuse Kits into Square D 100A Series F Safety Switches to...
Relocating Heavy Duty Safety Switch Load Base to Accept Class J Fuses | Schneider Electric Support
Tutorial for converting a Square D Heavy Duty Safety Switch to accept Class J fuses by relocating...
Installing SN0610 Neutral Assembly into an F-Series Heavy Duty Switch
Tutorial for installing a SN0610 solid neutral assembly into a Square D F-series heavy duty safety...
The name already exists. Please enter a unique name.
Already Exists
List created successfully
You successfully added the product to your list with minimum order quantity.
Product Added
List updated successfully
empty name
There was a problem adding this product to your list. This may be because your list already contains 50 items.